// Guides // FeNau
Gratings in underground and multi-storey car parks
Ventilation, drainage, de-icing salt: in a car park the grating has to do three things at once – let plenty of air through, carry vehicles and withstand salt water. What the car park regulations specify and which version lasts where.
1. Ventilation under car park regulations
The German model car park regulation (M-GarVO, Section 15) permits natural ventilation for medium-sized and large car parks if ventilation openings with a total free area of at least 1,500 cm² per parking space are provided, permanently open, in opposite external walls and arranged to create cross-ventilation. What counts is the free area of the opening – i.e. the area minus the bars:
| Grating in the ventilation opening | Free area | Gross area for 1,500 cm² | Rain protection / view |
|---|---|---|---|
| Press-locked grating 30/30 | ≈ 80 % | ≈ 1,900 cm² | open |
| Press-locked grating 30/10 | ≈ 70 % | ≈ 2,150 cm² | open, safe against small items |
| Louvre grating 60° | ≈ 50 % | ≈ 3,000 cm² | splash water, partial view |
| Louvre grating 45° / 30° | ≈ 30–40 % | ≈ 3,750–5,000 cm² | rain and privacy protection |
| Perforated plate (for comparison) | 25–50 % | 3,000–6,000 cm² | depending on perforation |
That is why the press-locked grating is the most efficient grille for ventilation openings – and a louvre grating only where rain or views are a real problem (weather side, housing opposite). Ventilation gratings in the ceiling slab (light well principle) must be walkable or trafficable if they lie in footpaths or yards – see light well grating and louvre grating. The specific design is determined by the ventilation/fire safety designer; we supply the free area for each grating type.
2. Channels and deck drainage
- Foot of ramp and entrance: channel grating across the direction of travel, span = channel width (150–300 mm), bearing bar 30 × 3 to 40 × 3 for cars, 50 × 3 for vans; anchored frame, 4 clips or bolts per grating (trafficable).
- Load class: car decks B125, delivery traffic C250 to DIN EN 124/1433 – “car” or “van” in the configurator.
- Mesh: 30/10 – tyres run more quietly, pedestrians do not trip, dirt stays on top; 30/30 only in pure driving lanes.
- Slot channels / point drains on decks: cover gratings to the clear dimension, height = channel rebate, secured against flipping up when driven over.
- Slip resistance on ramps (gradient up to 15 %): serrated bearing bar R12.
3. De-icing salt and material
In winter, vehicles bring in de-icing salt – splash water on channels and ramps corresponds to C5. Hot-dip galvanised gratings last 8–15 years there; for longer, use 316 stainless steel (1.4571/1.4404) for channels and ramps and galvanised for ventilation openings and slabs that see no salt water. 304 is the wrong place to save money with de-icing salt (pitting). Duplex (galvanised + coated) extends service life on channels but wears in driving lanes. Cleaning: flush channels in spring, do not spread salt on zinc gratings (materials).
4. Ramps, stairs, light wells, plant
- Escape stairs from the underground car park: grating stair treads with nosing, R11–R12, non-combustible – escape stairs.
- Light wells and emergency exits in yards and footpaths: walkable/trafficable according to location, burglary and child protection, 30/10 (light well).
- Plant rooms (transformer, UPS, sprinkler control): ventilation gratings as louvres against views, walkable cable duct covers, earthing.
- Charging stations: cable duct and foundation covers as gratings, trafficable at parking spaces, 30/10 against connector damage from small items.
- Car park façades: open car parks need façade openings of ≥ ⅓ of the wall area – grating or louvre panels as the façade, duplex in RAL, fall protection (façade).
Questions and answers
How large do ventilation openings in an underground car park need to be?
Under the German model car park regulation, naturally ventilated medium-sized and large car parks need at least 1,500 cm² of free area per parking space, permanently open, with cross-ventilation. A 30/30 press-locked grating has approx. 80 % free area, a louvre grating 30–50 % – the opening must be correspondingly larger.
Which grating for the drainage channel at the ramp?
Channel grating across the direction of travel, 30/10, bearing bar 30×3 to 40×3 (cars, B125) or 50×3 (delivery traffic, C250), anchored frame, 4 clips; serrated R12 on slopes.
Galvanised or stainless steel in an underground car park?
Channels and ramps with de-icing salt splash in 316 (zinc lasts only 8–15 years there, 304 suffers pitting); ventilation openings and slab gratings without salt contact hot-dip galvanised.
Rain is getting in through the ventilation opening – what can I do?
A louvre grating with 30° or 45° louvres (rain and privacy protection), with a larger opening to compensate for the lower free area; louvres draining outwards.
Can ventilation gratings be placed in footpaths?
Yes, if they are designed as walkable (1.5 kN) or trafficable at entrances, with mesh 30/10 (accessible, safe for heels) and secured against lifting.