// Guides // FeNau
Trafficable gratings: designing driveways, yards, channels and parking areas correctly
A trafficable grating is not just a thicker pedestrian grating – it needs different structural design, an anchored frame and fixings that withstand dynamic loads. Here is what that involves.
1. Load classes to DIN EN 124 / DIN EN 1433
| Class | Test load | Location | Grating practice |
|---|---|---|---|
| A 15 | 15 kN | Footpaths, pedestrian zones, green areas, cycle paths | pedestrian gratings with a margin |
| B 125 | 125 kN | Footpaths, pedestrian zones, car parking areas and decks | “car” use in the configurator |
| C 250 | 250 kN | Kerbside areas, hard shoulders, parking areas with delivery traffic | “van/lorry” – project-specific |
| D 400 | 400 kN | Carriageways, roads, paved hard shoulders | special gratings, on request |
The classes come from the standard for manhole covers and drainage channels (DIN EN 124, DIN EN 1433). For gratings as flooring, DIN 24537-1 with point and distributed loads formally applies – but the classes are the language planners, civil engineers and building authorities think in. The configurator converts them into wheel loads on 200 × 200 mm: cars from 4.5 kN, vans approx. 10 kN, lorries considerably more and project-specific – each with the safety factors to RAL-GZ 638.
2. Bearing bar by vehicle and span
For trafficable gratings, the point load (wheel) almost always governs, not the distributed load. Guide values from the bearing bar table (press-locked grating 33/33, S235):
| Span | Car (4.5 kN) | Van / small lorry (10 kN) | Lorry wheel (up to 16 kN) |
|---|---|---|---|
| 300 mm (channel) | 30 × 3 | 40 × 3 | 50 × 3 |
| 600 mm | 30 × 3 / 40 × 2 | 50 × 3 | 50 × 5 |
| 800 mm | 40 × 3 | 50 × 5 | 60 × 5 |
| 1000 mm | 40 × 3 / 50 × 3 | 50 × 5 | 60 × 5 |
| 1200 mm | 50 × 3 | 60 × 5 | intermediate support |
For genuine lorry carriageways (D 400) we calculate per project, often with double bearing bars or a closer pitch (22 mm). With vehicles, also note: bearing bars across the direction of travel, so the wheel loads several bars at once and the grating does not “sing”.
3. Channel gratings at driveways and garage doors
The most common trafficable grating is the drainage channel in front of the garage door or at the property boundary. Here:
- Span = channel width (usually 150–300 mm) – which is why moderate bearing bars (30 × 3 to 40 × 3) are enough despite car traffic, while pitch 33/11 or 30/10 keeps gravel and leaves on top.
- Anchored frame: angle frame with anchors in concrete, otherwise every pass pushes the edge outwards.
- Securing the grating: clips or bolts – channel gratings that flip up when driven over are the classic cause of tyre damage and injury.
- Slip resistance: with a slope towards the garage, a serrated bearing bar (R12).
- Lengths: gratings in 1000 mm pieces; corners and mitres to sketch. Standard channel gratings: trafficable channel gratings from FeNau.
4. Frame, clips, installation
- Frame: angle frame from 40 × 40 × 4 to 50 × 50 × 5 mm, height = bearing bar height, with welded-on anchors; set in C25/30 concrete, not just in grit.
- Support: level, full-surface, at least 30 mm; the grating must not rock on two corners (fatigue failure at the welds).
- Fixing: always under vehicle loads – 4 clips or bolts per grating (fixing guide, double clips).
- Level: top of grating flush with the paving or 2–3 mm lower, never higher – otherwise a snowplough or shovel will rip it out.
- Joints between several gratings: 3–5 mm, no gravel backfill under the support.
5. Typical mistakes
- Grating ordered as “pedestrian” because “a car only rarely stands on it” – structural design has no “rarely”.
- Bearing bars laid in the direction of travel – the wheel hits only two bars and the grating bends permanently.
- Grating laid directly on a concrete edge without a frame – the edge breaks away and the grating creeps.
- Wrong span: for a 300 × 1000 channel the span is 300, not 1000 – mix them up and you order 60 × 5 instead of 30 × 3.
- De-icing salt on a galvanised channel grating – rusted through after 5–8 winters; spread grit or choose 316 stainless steel (materials).
Questions and answers
Which grating do I need for a driveway?
Car-trafficable (at least 4.5 kN wheel load): for a 1000 mm span, a 40×3 to 50×3 bearing bar; for channels with a 300 mm span, 30×3; always with an anchored frame and clips, bearing bars across the direction of travel.
What does class B125 mean?
Load class to DIN EN 124 for areas used by cars (test load 125 kN) – footpaths, parking areas, yard entrances. In the configurator this corresponds to the car use.
Can a grating be lorry-trafficable?
Yes – for small spans (channels) with 50×3 to 60×5, for larger panels with intermediate supports, double bearing bars or a closer pitch. We design D400 carriageways per project.
Does a trafficable grating have to be fixed?
Yes, always: at least 4 clips or bolts per grating, in a frame anchored and cast in concrete. A grating that flips up is an accident.
Which mesh for a driveway?
30/10 or 30/20 – keeps gravel and leaves on top, tyres run more quietly and it is accessible for pedestrians.