// Guides // FeNau
Grating load & structural design – how the bearing bar is determined
A grating is a structural component. If you understand how bearing bar, span and load relate, you will order neither too weak nor too expensive. Here are the rules, tables and examples.
1. The terms: point load, distributed load, span
- Span (L): the free distance between the two supports, measured in the bearing bar direction. The first dimension in the configurator.
- Point load (FP): a concentrated load on a contact area of 200 × 200 mm – a foot, a wheel, a support foot. For gratings it is almost always the governing load.
- Distributed load (FV): evenly distributed load in kN/m² – crowds, stored material, snow.
- Bearing bar: height × thickness, e.g. 30 × 2 mm. The height enters the load capacity squared, the thickness linearly: 40 × 2 carries considerably more than 30 × 3, even though it weighs less.
- Pitch: spacing of the bearing bars (33 mm for 33/33 and 33/11). Closer pitch = more bars per metre = more load capacity per m².
1 kN is roughly 100 kg. So 1.5 kN is a heavy person carrying a load; 4.5 kN is one wheel of a loaded car.
2. The load cases that occur in practice
| Use | Point load FP | Distributed load FV | Source / note |
|---|---|---|---|
| Pedestrian (light well, walkway, terrace) | 1.5 kN | 5 kN/m² | DGUV Information 208-007, DIN EN ISO 14122-2 |
| Footpath / small areas (class A15) | 15 kN | – | DIN EN 124 / DIN EN 1433 – pedestrians and cyclists |
| Car parking space, driveway (class B125) | 125 kN test load* | – | DIN EN 124 – in practice wheel load 4.5–10 kN |
| Car park / yard | 20 kN | 2.5 kN/m² | DIN EN 1991-1-1 cat. F (vehicles ≤ 30 kN) |
| Van, forklift, lorry kerbside area (class C250) | 250 kN test load* | – | DIN EN 124 – design for the specific project |
| Carriageway (class D400) | 400 kN test load* | – | DIN EN 124 – special gratings, on request |
* The classes to DIN EN 124 are test loads for covers and channels, not wheel loads. For a custom grating they are converted into a point load on 200 × 200 mm; the configurator does this with its use types “pedestrian”, “car” and “van/lorry”. All values there include the usual safety factors.
3. Bearing bar table (press-locked grating 33/33, S235, to RAL-GZ 638)
Permissible distributed load FV (kN/m²) and point load FP (kN) per bearing bar for different spans, pitch 33 mm, steel S235JR:
| Bearing bar | 600 mm | 800 mm | 1000 mm | 1200 mm | 1500 mm | ≈ kg/m² |
|---|---|---|---|---|---|---|
| 25 × 2 | 19.6 / 2.17 | 11.0 / 1.55 | 7.0 / 1.21 | 4.9 / 0.99 | 3.1 / 0.78 | 18 |
| 30 × 2 | 28.2 / 3.10 | 15.9 / 2.22 | 10.2 / 1.72 | 7.0 / 1.41 | 4.5 / 1.11 | 21 |
| 30 × 3 | 42.3 / 4.65 | 23.8 / 3.32 | 15.2 / 2.58 | 10.6 / 2.11 | 6.8 / 1.66 | 30 |
| 40 × 2 | 50.1 / 5.41 | 28.2 / 3.87 | 18.1 / 3.01 | 12.5 / 2.46 | 8.0 / 1.93 | 26 |
| 40 × 3 | 75.2 / 8.12 | 42.3 / 5.80 | 27.1 / 4.51 | 18.8 / 3.69 | 12.0 / 2.90 | 37 |
| 50 × 3 | 117.5 / 12.46 | 66.1 / 8.90 | 42.3 / 6.92 | 29.4 / 5.66 | 18.8 / 4.45 | 45 |
| 50 × 5 | 195.9 / 20.76 | 110.2 / 14.83 | 70.5 / 11.54 | 49.0 / 9.44 | 31.3 / 7.42 | 62 |
| 60 × 5 | 282.0 / 29.34 | 158.6 / 20.96 | 101.5 / 16.30 | 70.5 / 13.34 | 45.1 / 10.48 | 72 |
How to read it: a 30 × 2 grating with a 1000 mm span carries 10.2 kN/m² distributed load or 1.72 kN point load – so the 1.5 kN for “pedestrian” with a margin. For a 2 kN point load at 1000 mm you already need 30 × 3 (2.58 kN). The table applies to pitch 33/33; for 33/11 and for electro-forged gratings the values differ slightly, and the configurator calculates with the exact data. To find the answer in seconds: bearing bar calculator.
4. Span: why 1.5 m is the economic limit
Load capacity falls with the square of the span. A grating with a 1500 mm span needs a bearing bar twice as high as one with 1000 mm for the same load – and weighs accordingly. From around 1.5 m clear span, an intermediate support (flat bar on edge, T or angle section, set in concrete or welded into the frame) is therefore almost always cheaper and easier to handle than a single heavy grating. Two panels of 750 mm instead of one of 1500 mm: bearing bar 25 × 2 instead of 40 × 3. In addition, gratings over 1500 × 1000 mm can hardly be laid without lifting gear (60 × 5 weighs 72 kg/m²).
5. Deflection: the often forgotten check
In addition to load capacity, RAL-GZ 638 limits deflection to 1/200 of the span (5 mm at 1000 mm). A grating that visibly deflects is not automatically unsafe, but it is springy, rattles and feels “wobbly” – on terraces, balconies and walkways that is the reason to choose a bearing bar one size up from what the structure requires. For trafficable gratings and gratings with a tile or timber covering, we recommend designing to L/300.
6. Everyday worked examples
- Light well 1000 × 500 mm, pedestrian, bearing bar towards the house wall (500 mm): span 500 mm → 25 × 2 is easily enough (already 2.17 kN at 600 mm). Often needlessly ordered as 30 × 3.
- Driveway channel 1200 × 300 mm, car: the span is the short side, 300 mm, bearing bars across the direction of travel → 30 × 3 or 40 × 3, frame anchored, clips mandatory.
- Terrace 2000 × 1000 mm, pedestrian: span 1000 mm → 30 × 2 (1.72 kN) is sufficient, but 30 × 3 or 40 × 2 is recommended for deflection and feel underfoot; better still, an intermediate support at 1000 mm and two gratings of 1000 × 1000.
- Data centre duct cover 600 × 600 mm, pallet truck 10 kN: span 600 mm → 50 × 3 (12.46 kN); for server cabinets with point loads on levelling feet, check for the specific project.
Questions and answers
Which bearing bar do I need for a pedestrian grating?
For a 1.5 kN point load, 25×2 is sufficient up to approx. 1000 mm span, 30×2 up to approx. 1200 mm and 30×3 up to around 1500 mm (pitch 33/33, S235).
What does a point load on 200×200 mm mean?
A concentrated load applied over an area of 200×200 mm – the size of a foot or a wheel contact patch. It loads only a few bearing bars and is therefore almost always the governing load case for gratings.
How much does a 30×2 grating carry over a 1000 mm span?
10.2 kN/m² distributed load or 1.72 kN point load to RAL-GZ 638 (press-locked grating 33/33, S235).
What deflection is permissible for gratings?
RAL-GZ 638 limits deflection under service load to 1/200 of the span, i.e. 5 mm at 1000 mm.
Is the bearing bar direction really that important?
Yes. Only the bearing bars carry load from support to support. A grating laid rotated by 90° rests on its cross bars and can break through under load.