// Guides // FeNau
Grating mesh size: 30/30, 30/20 or 30/10?
The mesh decides what falls through the grating – leaves, heels, walking-stick tips, screws – and whether the grating is permitted on public paths at all. Here is the decision guide with all the standard values.
1. Mesh and pitch – two figures for the same thing
The pitch is the centre-to-centre distance of the bars (e.g. 33 × 33 mm), the mesh size the clear opening between them (30 × 30 mm with 2 mm bars, 30 × 30 with pitch 33 for 3 mm bars). Manufacturers and standards state the pitch, customers the mesh. The first figure is always the spacing of the bearing bars, the second that of the cross bars. So 33/11 means: bearing bars every 33 mm, cross bars every 11 mm – a clear mesh of approx. 30 × 10 mm (hence “30/10”). The exact designation is explained in the grating types guide.
2. What the standards require
| Area | Requirement | Regulation | Mesh |
|---|---|---|---|
| Industrial platforms, walkways | A ball of Ø 35 mm must not fall through | DIN EN ISO 14122-2 | 30/30 complies (max. 30 mm) |
| Above workstations / traffic routes | Openings max. 20 mm (falling objects) | DIN EN ISO 14122-2 | 30/20 or 30/10 |
| Accessible routes, entrances | Safe for wheelchairs, rollators and canes – openings in the walking direction ≤ 10 mm (in practice) | DIN 18040-1/-3 | 30/10 across the walking direction |
| Workplaces, traffic routes | Sure footing, safe for heels and canes | ASR A1.8, ASR A1.5/1,2 | 30/10 in public areas |
| Swimming pools, barefoot areas | Openings ≤ 8 mm (finger entrapment protection) | DIN EN 13451-1 | Barefoot pitch, 30/10 only with 8 mm verification |
| Playgrounds, nurseries | Avoid finger traps: openings < 8 mm or > 25 mm | DIN EN 1176-1 | 30/30 or barefoot pitch, not 30/10–30/20 |
3. The three standard meshes compared
| 30/30 (33/33) | 30/20 | 30/10 (33/11) | |
|---|---|---|---|
| Free area | ≈ 80 % | ≈ 75 % | ≈ 70 % |
| Light into the basement | maximum | high | good |
| Holds back | coarse items | small items, coarse leaves | leaves, heels, sticks, gravel, mice |
| Safe for heels/canes | no | no | yes (laid crosswise) |
| Load capacity | the same – it depends only on the bearing bar, not on the cross bar pitch | ||
| Price | base | + | ++ (more cross bars, more work) |
| Typical | Industry, halls, yards, garden wells | Industry above workstations, plant rooms | Entrances, footpaths, shops, schools, hospitals, house surrounds |
4. Which mesh where – the short rule
- Basement and light wells in the garden: 30/30 – light is what counts.
- Anywhere strangers walk (entrance, footpath, shop, school, surgery, hotel): 30/10 – accessible and safe for heels.
- Driveway, yard with vehicles: 30/10 or 30/20 – gravel and leaves stay on top, tyres run more quietly.
- Industry, walkways, platforms: 30/30; with workstations below → 30/20 or 30/10.
- Data centres, plant rooms: 30/10 – screws and cable ties do not fall into the raised floor (more).
- Swimming pool, sauna, house surround with children: openings ≤ 8 mm, barefoot pitch (more).
- Ventilation, heat pump: 30/30 – maximum airflow, unless leaves are a problem (more).
5. Laying direction: the fine mesh must lie crosswise
The heel and cane safety of the 30/10 mesh only applies if the narrow dimension (10 mm) lies across the walking direction. Because the cross bars form the fine pitch and always run at right angles to the bearing bars, this means: the bearing bars run in the walking direction. At entrances and on footpaths, the bearing bar direction must therefore be planned according to the walking direction, not just the supports – with an intermediate support if necessary. In the configurator, the first dimension is always the bearing bar direction.
Questions and answers
What does mesh size 30/10 mean for a grating?
Clear opening of approx. 30 mm between the bearing bars and approx. 10 mm between the cross bars (pitch 33/11). The fine mesh is safe for heels and canes and holds back leaves.
Which mesh size is accessible?
DIN 18040 requires gratings to be safely passable with wheelchairs, rollators and white canes; in practice openings ≤ 10 mm in the walking direction – i.e. 30/10 with the narrow dimension across the walking direction.
Does a 30/10 grating carry more than 30/30?
No, load capacity depends only on the bearing bar (height × thickness) and the bearing bar pitch. The closer cross bars only add weight and cost.
Which openings are permitted on industrial platforms?
Under DIN EN ISO 14122-2, a ball with a diameter of 35 mm must not fall through; above workstations where parts could fall, a maximum of 20 mm.
Which mesh for barefoot areas?
DIN EN 13451-1 requires openings ≤ 8 mm to protect against finger entrapment – a special barefoot pitch or 30/10 with appropriate verification, in 316 stainless steel for chlorinated water.