// Guides // FeNau
Gratings for light wells – the complete guide
The light well grating is the most common grating around the house – and the one most often ordered wrongly. Here is what matters: from measuring to mesh and load capacity through to burglary protection.
1. Measuring correctly: the clear dimension counts
Measure the clear internal dimension of the frame the grating will sit in – not the old grating (it may be deformed) and not the outer edge of the light well. Measure each direction in at least two places (front/back or left/right) and use the smaller value. We manufacture to RAL-GZ 638 with a tolerance of +0 / −4 mm: the grating is never larger than ordered, and the necessary fitting clearance is included in the tolerance. So you do not need to deduct anything.
- Plastic frames (prefabricated light wells) are often slightly tapered – measure at the top, where the grating sits.
- For masonry or concrete wells without a frame: measure the bearing surface and order a frame as well.
- Smooth uneven supports (old render, mortar residue) before installation – a grating that rocks will rattle and wear through the galvanising.
2. The bearing bar direction: from the well edge to the house wall
The bearing bars must run from support to support – for a light well, usually from the well edge to the house wall, because that is where the two stable supports are. The first dimension in the configurator is always this bearing bar direction (span), the second is the width. A grating with the dimensions swapped rests only on its cross bars and carries practically nothing. Each bearing bar needs at least 20–30 mm of bearing length at each end.
3. Mesh 30/10 or 30/30?
There is no regulation on the mesh for a light well – but there are clear rules of thumb:
| Mesh (pitch) | Light | Holds back | Recommendation |
|---|---|---|---|
| 30/30 mm (33/33) | maximum, ≈ 80 % open | coarse items only | Wells in the garden, yard, behind the house |
| 30/20 mm | high | small items, coarse leaves | Compromise if 30/10 is too dark |
| 30/10 mm (33/11) | good, ≈ 70 % open | leaves, heels, walking-stick tips, small animals | Entrances, footpaths, driveways, terraces (DIN 18040) |
If the well is next to a footpath, at the front door or in a publicly accessible area, choose 30/10 – because of heels, rollators and pushchairs, and because the fine mesh holds back leaves that would otherwise block the drain in the well. More on this in the mesh size guide.
4. Pedestrian or trafficable?
For a light well at a house, the standard pedestrian design (1.5 kN point load on 200 × 200 mm, 5 kN/m²) to DGUV Information 208-007 is sufficient. For a well width of 1000 mm that means a 30 × 2 mm bearing bar; for 600–800 mm, 25 × 2 mm is enough. If the well is in a driveway, a parking space or at the roadside, the grating must be designed as trafficable – cars from 4.5 kN wheel load, typically a 40 × 3 to 50 × 3 mm bearing bar for a 1000 mm span, and the frame must be anchored. All values are in the load & structural design guide; the configurator selects the bearing bar automatically.
5. Frame: when you need one
Prefabricated plastic or concrete light wells usually have a bearing rim – the grating rests there without a frame. For masonry wells, concrete upstands or openings enlarged later, the grating needs an angle frame as a clean, level support. The frame is cast in concrete or fixed with anchors, galvanised or in stainless steel to match the grating, and can be selected directly in the configurator. For trafficable gratings an anchored frame is mandatory, otherwise the grating creeps with every pass. Standard frames are also available at FeNau frames & surrounds.
6. Burglary and lift-out protection
A loosely laid light well grating can be lifted in seconds – burglars know that too. Police crime prevention advisers therefore recommend securing light well gratings against lifting. Options, from simple to solid:
- Grating lock / safety chain – screwed to the well; the grating can still be removed for cleaning (locks from FeNau).
- Lockable clips or fixing from the inside (accessible only from the basement).
- Anchored frame + clips – the most robust solution, and mandatory for trafficable gratings anyway.
Every grating should be secured even without burglary in mind: it must not slip or tip under pedestrians (DGUV Information 208-007). How to do it is explained in the fixing guide.
7. Replacing an old grating – what is often forgotten
- Do not measure the old grating, measure the opening – old gratings are often too small (clearance) or bent.
- Check the height: a new grating with a 30 mm bearing bar will not fit a frame built for 20 mm. Overall height = bearing bar height.
- Order cut-outs for downpipes, ventilation pipes or cables at the same time – cutting afterwards destroys the galvanising.
- Several wells: measure each one individually; dimensions of identical wells regularly differ by 5–10 mm.
Questions and answers
Which grating fits my light well?
Measure the clear internal dimension of the well frame, enter the bearing bar direction (well edge to house wall) as the first dimension and choose pedestrian for wells at the house or trafficable for wells in driveways. The configurator calculates the right bearing bar.
Do I need to deduct anything from the measured size?
No. We manufacture to RAL-GZ 638 with a tolerance of +0/−4 mm; the grating is never larger than ordered and the fitting clearance is included.
Which mesh is right for a light well?
30/30 for maximum light in the garden or yard; 30/10 if the well is at entrances, on footpaths or in the driveway – because of heels, castors, leaves and DIN 18040.
How do I secure a light well grating against burglary?
With a grating lock or safety chain, lockable clips or an anchored frame with clips. The grating can still be removed for cleaning but cannot be lifted from outside.
Does a custom grating also fit plastic light wells from common manufacturers?
Yes. Measure the clear dimension at the top edge of the well and the height of the support; we make any intermediate size and, on request, with cut-outs.