// Guides // FeNau

Louvre and lamella gratings: ventilation without letting in rain or prying eyes

A normal grating lets everything through – air, light, rain, leaves, views. A louvre grating only lets through what it should. How it is built, where it proves itself and what to watch for when ordering and installing.

1. Design and effect

The louvre grating (also lamella grating, weather-protection grating, type RL) is a press-locked grating in which the vertical cross bars are replaced by louvres pressed in at an angle. The load-bearing grid of flat bars on edge remains – so the grating carries loads according to the same structural design as a press-locked grating (RAL-GZ 638) and is walkable, and trafficable on request. The louvres are set at 30°, 45° or 60°:

Louvre angleTransparency / viewAirflowRain & sun protectionTypical
30°low – almost closed in the line of sightreducedvery goodPrivacy, weather side, brise-soleil
45°mediumgoodgoodVentilation openings, façade, light well
60°high – noticeably more openhighsplash waterVentilation with high volume flow, cold aisle

The louvre height and pitch further adjust the field of view: tall louvres at a close pitch overlap completely in plan, low ones at a wide pitch allow a view downwards. Louvres are available as a standard profile, Z profile or L profile – Z and L create an additional drip edge or a closed façade appearance. Depending on angle and pitch, the free area is around 30–50 % (open press-locked grating: 70–80 %).

Dimensions and materials

  • Bearing bars 30 × 2 to 70 × 2 mm and 30 × 3 to 70 × 3 mm – according to span and load.
  • Louvres 25 × 2 to 40 × 2 mm and 25 × 3 to 40 × 3 mm.
  • Edge strip 5 mm flat bar all round, cut-outs and free shapes (bevels, radii) possible.
  • Steel hot-dip galvanised, duplex (galvanised + powder-coated in any RAL colour, one or two coats), stainless steel pickled, aluminium anodised – see materials.

2. Where a louvre grating is the right choice

  • Light wells and basement windows on the weather side: driving rain and leaves stay out, the basement stays dry and ventilated – no more blocked well drains.
  • Ventilation openings in underground car parks: supply and extract air in line with car park regulations, without rain and without views from the street.
  • Plant rooms, transformer stations, heating and ventilation plant rooms: supply air for combustion and cooling, weather protection for the equipment.
  • Data centres: directed supply air in the cold aisle, free-cooling openings in façade and plinth (more).
  • Façades and cladding: brise-soleil sun shading, car park and plant façades, screening of outdoor units (heat pumps, air-conditioning units) with airflow, powder-coated in the façade colour or anodised aluminium.
  • Privacy screens, fences, balcony balustrades: louvres as an architectural element – views limited, air and light retained; Z/L profile for a calm façade appearance.
  • Covers for pits used below: cable and services pits that neither water nor eyes should get into.

3. Selection and specification

FeatureOptionsNote
Louvre angle30°, 45°, 60°30° = privacy/weather, 45° = all-round, 60° = maximum airflow
Louvre profilestandard, Z profile, L profileZ/L with drip edge or closed façade appearance
Louvre directiontowards / away from the façade, to the left/rightwater must drain away from the building – state when ordering
Bearing bar / louvrebearing bar 30×2 – 70×3, louvre 25×2 – 40×3 mmas press-locked grating: pedestrian 1.5 kN, trafficable according to structural design
Materialsteel hot-dip galvanised, duplex powder-coated (RAL, 1 or 2 coats), stainless steel pickled, aluminium anodisedfaçade: duplex in the façade colour or aluminium; coast/de-icing salt: 316
Dimensionsmade to measure, with cut-outs, frameseveral panels with continuous louvre alignment
Slip resistancelouvre top edge smooth or serratedserrated recommended for outdoor foot traffic

Louvre gratings are special gratings: send an enquiry with dimensions, angle, direction and location via the contact form – lead times as for special products. For ventilation gratings in standard sizes and design covers, see also SEPGRATE design covers.

4. Installation: three things to clarify beforehand

  • Drainage direction: the louvres must direct water away from the building or into the well with a drain – check the louvre direction against the installed position before ordering.
  • Air requirement: ventilation designers specify the required free area (e.g. for boiler rooms or underground car parks); a louvre grating has less open area than an open grating, so size it larger if necessary.
  • Cleaning: louvres catch leaves and dust – install the grating so it can be removed (frame, clips rather than bolts) and hose it down once a year.

Questions and answers

What is a louvre grating?

A press-locked grating in which angled louvres replace the vertical cross bars. Air flows through in a directed way, while rain, splash water and views stay out; walkable like a normal grating.

How much air does a louvre grating let through?

Depending on louvre angle (30°, 45°, 60°) and pitch, around 30–50 % free area – less than an open grating (70–80 %), but weather-protected. Size it larger accordingly if the air requirement is specified.

Is a louvre grating walkable or trafficable?

Always walkable (bearing bars as in a press-locked grating); trafficable with a suitable bearing bar and an anchored frame according to structural design.

Can I get a louvre grating in the façade colour?

Yes, as a duplex system hot-dip galvanised and powder-coated in any RAL colour, or in stainless steel.

How do I order a louvre grating?

As a special grating via the contact form, with dimensions, bearing bar direction, louvre angle and direction, material and location – we will send a quotation with a drawing.