// Guides // FeNau
Grating stair treads and stairs: tread size, nosing, slip resistance
Stair treads are the most demanding application for gratings: they are stepped on at the edge, used outdoors in icy conditions and serve as the escape route in a fire. What DIN EN ISO 14122-3 and the workplace regulations require and how to order treads.
1. How a grating stair tread is built
A grating stair tread is a press-locked or electro-forged grating panel with bearing bars parallel to the tread edge, a safety nosing at the front (perforated, serrated sheet-metal profile, slip-resistant and contrasting) and two end plates (tread brackets) with holes for bolting to the stair stringer. The bearing bars run across the walking direction because that way they span from stringer to stringer – and because serrated bearing bars only give grip across the walking direction.
2. Dimensions
| Dimension | Usual values | Note |
|---|---|---|
| Tread width (span) | 600, 700, 800, 900, 1000, 1200 mm; made to measure up to approx. 1500 mm | Width = span → bearing bar grows with width |
| Tread depth (going) | 240, 270, 305 mm | according to the stair's rise-to-going ratio (2 r + g = 59–65 cm) |
| Bearing bar | 30 × 2 to 40 × 3 | Point load 1.5 kN at mid-tread; industry often 3 kN |
| Mesh | 30/30 industry; 30/10 public areas | Ball test 35 mm, 20 mm above workstations (DIN EN ISO 14122-2) |
| Nosing | serrated, perforated, height ≈ bearing bar height | can also be retrofitted: safety nosing |
| Hole spacing of end plates | to the stair builder / existing stair | when replacing, measure the old tread |
3. What the standards require for stairs
- DIN EN ISO 14122-3 (stairs, stepladders and guard-rails on machinery): slip-resistant treads, nosing, equal risers, openings as for platforms; going ≥ 210 mm (≥ 240 mm recommended for industry).
- ASR A1.8 / DGUV Rule 108-003: external stairs in workplaces R11 to R12; tread edge marked in a contrasting colour; treads above workstations with a small mesh.
- DIN 18065 (stairs in buildings): rise-to-going ratio, minimum going; grating treads in buildings are mostly used for external, basement and escape stairs.
- Escape stairs: non-combustible (steel A1), slip-resistant even when wet, open enough to prevent snow and ice build-up – which is why grating treads are the standard for external escape stairs.
- DIN 24531-1: dimensions and design of grating stair treads (standard treads) – the basis of the standard ranges.
4. Tread types in the FeNau range
| Tread | Property | Use |
|---|---|---|
| Press-locked treads (standard) | Mesh 30/30 or 30/10, serrated nosing, R10–R11 | External stairs, basements, industry |
| Treads with slip resistance R10 | Tested slip resistance to DIN 51130 | Traffic routes in workplaces |
| Electro-forged treads | Robust, economical, twisted cross bars | Industry, platforms, plant |
| MEASTEP XSL escape stair treads | Close mesh, safe for heels, nosing | Escape stairs, public buildings |
| Sheet-metal treads | Light, folded from perforated sheet | Ladders, maintenance stairs, small spans |
| Custom treads | Special widths, stainless steel, mitres, landings with nosing | On request; press-locked landing gratings with nosing |
5. Installation and replacement
- Bolting the tread brackets to the stringer with M10/M12, galvanised or stainless steel; when replacing, measure the hole spacing on the old tread (tread accessories).
- Equal risers: a different tread height is a trip hazard – keep the bearing bar height of the old tread when replacing.
- Nosing at the front, serrated side up – sounds trivial, but it is the most common installation question.
- Landings: landing gratings with nosing on the exit side, clips against slipping (fixing).
- Outdoors: hot-dip galvanised is enough; stainless steel in de-icing salt areas; powder coating only on zinc (duplex) and not on the walking surface.
Questions and answers
What standard sizes do grating stair treads come in?
Widths 600–1200 mm (made to measure up to approx. 1500 mm), depths 240, 270 and 305 mm, bearing bar 30×2 to 40×3, with safety nosing and end brackets for bolting.
Does a grating stair tread need a nosing?
Yes – DIN EN ISO 14122-3 and the German workplace regulations (ASR) require slip-resistant, contrasting tread edges. A safety nosing can be retrofitted to existing treads.
What slip resistance do external stairs need?
Under DGUV Rule 108-003, R11 to R12 – grating stair treads with a serrated bearing bar and serrated nosing meet this.
Why do the bearing bars run crosswise on treads?
They span from stringer to stringer, and serrated bearing bars only give grip across the walking direction.
Are grating stair treads available in stainless steel or special sizes?
Yes, on request via the contact form – special widths, 304/316 stainless steel, mitred treads and landings with nosing.