The external steel stair is the classic second escape route – and grating treads are its standard surface: non-combustible, self-draining, slip-resistant, light. What German building regulations, DIN 18065 and DIN EN ISO 14122-3 require and how treads on existing stairs are replaced.
1. Escape route and building regulations
Under the German model building code (Section 33 MBO), every unit of use with habitable rooms must have two independent escape routes. The second can be an external staircase if its use is sufficiently safe and it is not endangered in a fire – in practice this means: non-combustible components (steel, grating: material class A1), distance from or protection against windows, safe use even in wet, snow and darkness. That is exactly why grating is the surface for escape stairs: snow falls through, water does not stand, ice hardly forms and the tread stays grippy. The state building codes and approval by the building authority or fire safety concept are decisive – we supply the surface data (A1, R class, load capacity) for the evidence.
2. Tread and stair dimensions
| Dimension | Building stair (DIN 18065, required stair in housing) | Machinery/industrial stair (DIN EN ISO 14122-3) |
|---|---|---|
| Rise r | 14 – 19 cm (≤ 2 dwellings: up to 20 cm) | up to 25 cm; pitch 30–38° recommended |
| Going g | 26 – 37 cm | ≥ 21 cm (≥ 24 cm recommended) |
| Step rule | 2 r + g = 59 – 65 cm | 2 r + g = 60 – 66 cm |
| Clear width | ≥ 80 cm (≤ 2 dwellings), otherwise ≥ 100 cm | ≥ 60 cm, 80 cm recommended |
| Landing | after max. 18 risers | after max. 3 m height or 18 treads |
| Handrail / railing | ≥ 90 cm, 110 cm from a fall height of 12 m; handrails on both sides from 150 cm width | Railing 110 cm, knee rail, kick plate 10 cm |
Grating stair treads in the standard depths of 240, 270 and 305 mm cover both sets of rules; the width depends on the clear distance between stringers (600–1200 mm standard, made to measure up to approx. 1500 mm).
3. The right tread
- Press-locked tread 30/30 or 30/10 with serrated safety nosing – standard for escape stairs on residential and office buildings; 30/10 in public buildings (safe for heels, schools, hospitals).
- Close-mesh escape stair treads (XSL type) with nosing: greater sure-footedness, the mandatory level for places of assembly and schools – escape stair treads.
- Slip resistance: external stairs in workplaces R11–R12 (DGUV 108-003) – serrated bearing bar, tested R10 treads for traffic routes; recommended for private use, not mandatory.
- Bearing bar 30 × 2 to 40 × 3 depending on width; point load 1.5 kN at mid-tread, for escape stairs crowd loading of 5 kN/m² on landings.
- Material: hot-dip galvanised (A1, 30–50 years); duplex in the façade colour; stainless steel on the coast/with de-icing salt. No coating on the walking surface.
- Contrast: a perforated/serrated nosing acts visually as a step marking – for escape stairs also lighting to ASR A3.4 / emergency lighting.
4. Landings, railings, drainage
- Landing gratings with nosing on the exit side (press-locked landing gratings), same mesh as the treads, clips against slipping.
- Railing ≥ 110 cm for escape stairs, infill without a ladder effect, openings ≤ 12 cm (children), kick plate on landings.
- Drainage: treads and landings drain through the grating – no puddles on footpaths below (channel or gravel strip); watch for splash water at underground car park entrances.
- Noise: grating treads ring – on residential buildings, tread brackets with rubber pads (grating supports) or bolt the treads instead of clipping them.
- CE / structural design: the load-bearing stair structure to DIN EN 1090 comes from the steel fabricator; we supply treads, landings and fixings with a declaration of conformity to RAL-GZ 638.
5. Replacing treads on existing stairs
- Measure the old tread: width between the stringers (clear dimension), going, bearing bar height, hole spacing and hole diameter of the end brackets.
- Choose the same bearing bar height – otherwise there will be a level difference to the next tread (trip hazard, not permitted).
- Retrofit a nosing if the old tread had none: bolt-on safety nosing.
- Bolting M10/M12 galvanised or A2/A4; do not reuse old bolts (tread accessories).
- With distorted stringers or corroded supports: call in a steel fabricator – the tread is only as safe as its stringer.
Questions and answers
Can an external stair with grating treads serve as a second escape route?
Yes, if the state building code permits the external stair as a second escape route and it is not endangered in a fire. Steel and grating are non-combustible (A1); evidence via the fire safety concept or building authority.
Which tread dimensions apply to external stairs?
Residential buildings to DIN 18065: rise 14–19 cm, going 26–37 cm, 2r+g = 59–65 cm, width ≥ 80/100 cm. Grating stair treads come in depths of 240, 270 and 305 mm.
What slip resistance do escape stair treads need?
In workplaces R11–R12 (DGUV Rule 108-003) – serrated bearing bar and serrated nosing. Not mandatory for private use, but strongly recommended.
How do I replace a single grating stair tread?
Measure the clear stringer dimension, going, bearing bar height and hole pattern of the old tread, order the same height (no level difference), fit with new M10/M12 bolts; a nosing can be retrofitted.
Why do grating stair treads rattle and what helps?
Play between the tread bracket and stringer. Remedy: tighten the bolts, rubber grating pads under the brackets, clips instead of loose support on landings.